Liquid Oxygen Plant Capacity Specifications: How Capacity Is Stated, Converted And Verified
Nov 26 , 2026Liquid Oxygen Plant Capacity Specifications Are Never a Single Number. A Proper Specification States At Least Four Separate Outputs, Each With Its Own Reference Conditions, And One Of Them Is Usually The Constraint That Decides The Size Of The Machine.
The Four Capacity Figures You Must Specify, And Never Merge Into One Headline:
· Gaseous Oxygen Output At The Battery Limit, Usually In Nm³/h, With Purity And Pressure.
· Liquid Oxygen Output, Usually In Tonnes Per Day Or Nm³/h Of Liquid Vaporised Equivalent, With Storage Temperature And Tank Pressure.
· Nitrogen Output, Gaseous And Liquid, Which Is The Usual By-Product Balance That Sets The Column Design.
· Argon Output, Only Where An Argon Column Is Included, Which Changes The Cold Box And The Power Figure.
A Fifth Figure Appears On Some Quotations: Air Feed To The Cold Box. It Is An Internal Design Number Rather Than a Deliverable, But It Is The Fastest Way To Test Whether a Proposed Machine Is Credible. If An Offer Quotes High Oxygen Output With An Unremarkably Small Air Feed, Ask For The Mass Balance.
Liquid Oxygen Plant Capacity Specifications Go Wrong When a Buyer Compares a Gas Figure From One Supplier Against a Liquid Figure From Another. That Single Unit Mismatch Produces More Rework In This Equipment Class Than Any Other Specification Error, Because Both Numbers Look Reasonable In a Spreadsheet.
Nm³, Sm³ And Scf All Describe Gas Volume At Different Reference Temperatures, So The Number Changes With The Basis. State The Basis Next To Every Volume Figure, Or The Comparison Is Meaningless.
|
Unit |
Reference Condition |
Common Use |
|
Nm³ |
0 °C, 101.325 Kpa |
Chinese And European Plant Ratings, Air Separation Unit Output |
|
Sm³ |
15 °C, 101.325 Kpa |
Commercial Gas Contracts, Some Middle East And Asian Projects |
|
Scf, Scfh |
60 °F, 1 Atm |
United States Procurement Documents |
|
Kg/h, t/d |
Mass Basis, No Temperature Dependence |
Liquid Product, Tanker Loading, Cylinder Filling Planning |
|
L, m³ Of Liquid |
Measured At The Cryogenic Temperature |
Tank Sizing, Filling Volumes |
The Temperature Matters Because Gas Volume Scales With Absolute Temperature At Constant Pressure. Moving From a 0 °C Basis To a 15 °C Basis Increases The Stated Volume By Roughly 5.5% For The Same Physical Quantity Of Gas. A Plant Quoted At 1,000 Nm³/h And a Plant Quoted At 1,050 Sm³/h Are Therefore Close To The Same Machine, Not a 5% Better One.
Mass-Based Units Avoid The Problem Entirely For Liquid Products, Which Is Why Serious Liquid Oxygen Plant Capacity Specifications State Tonnes Per Day For The Liquid Stream And Reserve Volumetric Units For Gas Delivery.
Use The Molar Volume And The Liquid Density, Then Label The Reference Temperature. Liquid Oxygen Is About 1.141 Kg Per Litre, And One Mole Of An Ideal Gas Occupies About 22.414 Litres At 0 °C And One Atmosphere.
From Those Two Published Physical Constants, The Conversions For Oxygen Follow Arithmetically:
|
Conversion |
Value |
Basis |
|
Liquid Oxygen Density |
1,141 Kg Per m³ |
Saturated Liquid At Atmospheric Pressure, About -183 °C |
|
One Tonne Of Lox, As Liquid Volume |
About 876 Litres |
1,000 Kg Divided By 1,141 Kg Per m³ |
|
One Tonne Of Lox As Gas At 0 °C |
About 700 Nm³ |
31.25 Kmol Multiplied By 22.414 Nm³ Per Kmol |
|
One Tonne Of Lox As Gas At 15 °C |
About 739 Sm³ |
Same Moles At 288.15 K |
|
One Tonne Of Lox As Gas At 20 °C |
About 752 m³ |
Same Moles At 293.15 K |
|
Volume Expansion, Liquid To Gas Near 20 °C |
About 860 Times |
876 Litres Of Liquid To About 752,000 Litres Of Gas |
|
One Litre Per Minute Of Lox, As Gas |
About 48 Nm³/h |
68.5 Kg/h Of Liquid Oxygen |
Every Liquid Oxygen Plant Capacity Specifications Document Should Carry These Constants On Its Face, So That Quotations Can Be Reconciled Without Re-Deriving Them. Two Practical Notes. First, The Widely Quoted Figure Of Roughly 750 Cubic Metres Of Gas Per Tonne Is a 20 °C Volume, Not a Normal Cubic Metre Figure. Where a Contract Uses Nm³, Use 700 Per Tonne. Second, Real Oxygen Deviates Slightly From Ideal Gas Behaviour, So Treat These Values As Planning Figures And Require The Supplier's Rated Figures For Guarantee Purposes.
Worked Example. A Bottling Plant Must Fill 6,000 Cylinders Per Day, Each With 40 Litres Of Water Capacity At 150 Bar. Each Cylinder Therefore Holds Roughly 6,000 Litres Of Free Gas, About 6 Cubic Metres, So 6,000 Cylinders Is About 36,000 Cubic Metres Of Oxygen Per Day Before Losses. Divided By 700 Nm³ Per Tonne, That Is Roughly 51 Tonnes Of Liquid Oxygen Per Day, And About 57 Tonnes Once Filling Residuals And Evaporation Losses Are Included. A Plant Rated Near 60 Tonnes Per Day Is Then The Number To Discuss With a Supplier. The Cylinder Count, Fill Pressure, Residual Fraction And Loss Rate Must Come From Your Own Filling Records, And a Production Figure Should Use The Compressibility Of Oxygen At The Actual Fill Pressure Rather Than The Ideal-Gas Shortcut Used Here.
State The Purity, The Measurement Point And The Analyser Basis. A Percentage Without a Location And a Method Is a Description, Not a Guarantee.
Cryogenic Separation Delivers Oxygen Purity In a Range That Psa Cannot Normally Reach. Common Published Grades:
|
Grade Band |
Typical O2 Content |
Typical Destination |
|
Psa Or Vpsa Oxygen |
90% To 95% |
Metal Cutting, Wastewater, Aquaculture |
|
Standard Cryogenic Oxygen |
99.5% To 99.6% |
Industrial Combustion, Chemical Oxidation, Liquid Product |
|
High-Purity Cryogenic Oxygen |
Above 99.6%, To 99.9% On Request |
Electronics, Speciality Chemical, Some Medical Duty |
|
Medical Oxygen |
Set By The Applicable Pharmacopoeia |
Hospital And Clinical Supply, Subject To Registration |
Purity Belongs In Liquid Oxygen Plant Capacity Specifications Because It Changes Output, Not Merely Quality. Put The Measurement Point At The Battery Limit, Not At The Column Outlet, And Name The Analyser Technology And Calibration Basis. Then State Whether Purity Is Guaranteed During Steady Operation Only, Or Also During Start-Up, Load Change And Recovery After a Trip. Those Transient Windows Are Where An Otherwise Compliant Plant Fails An Audit.
Sixteen Fields. If a Quotation Answers All Sixteen, Two Offers Can Be Compared Line By Line; If It Answers Fewer, You Are Comparing Documents Rather Than Machines.
|
Field |
What To State |
|
Gaseous Oxygen Output |
Nm³/h At The Battery Limit, With Tolerance |
|
Liquid Oxygen Output |
t/d Or Nm³/h Liquid Equivalent |
|
Nitrogen Output, Gas And Liquid |
Nm³/h And t/d, With Purity Basis |
|
Argon Output |
Required Or Excluded, With Purity |
|
Oxygen Purity |
Percentage, Measurement Point, Analyser Basis |
|
Delivery Pressure |
Barg Or Mpa At The Battery Limit |
|
Delivery Temperature |
Ambient, Or a Stated Range For Gas Product |
|
Liquid Storage Pressure And Temperature |
Tank Design Point |
|
Specific Energy |
Kwh Per Nm³ O2, With The Boundary Of Measurement |
|
Air Feed To Cold Box |
Nm³/h, As a Design Cross-Check |
|
Turndown Range |
Guaranteed Minimum And Maximum Load |
|
Cold Start Time |
Hours From Ambient To First Liquid Product |
|
Restart Time After Trip |
Minutes Or Hours To On-Spec Product |
|
Design Ambient Conditions |
Temperature Extremes, Humidity, Elevation, Coastal Exposure |
|
Utility Limits |
Voltage, Frequency, Available Starting Capacity, Cooling Water Temperature And Quality |
|
Duty Basis |
Operating Hours Per Year And Continuity Requirement |
Liquid Oxygen Plant Capacity Specifications Are Only Enforceable When Both Of Those Exist. Add Two Commercial Fields If Your Finance Team Reviews The Case: The Guarantee Remedy For a Missed Figure, And The Acceptance Test That Proves It. Liquid Oxygen Plant Capacity Specifications Become Enforceable Only When The Test Method And The Shortfall Value Are Written Alongside The Number.
Heat, Altitude And Cooling Water Temperature. A Plant Rated At Reference Conditions Can Deliver Less On a Hot Day At Elevation, And The Rating Basis Decides By How Much.
Four Mechanisms Matter In Practice:
1. Inlet Air Temperature. Warmer Inlet Air Is Less Dense, So The Compressor Moves Less Mass For The Same Volume. Capacity Falls And Specific Energy Rises.
2. Elevation. Lower Ambient Pressure Reduces Mass Flow Into The Same Machine At The Same Speed.
3. Cooling Medium Temperature. Pre-Cooling And Condensing Duty Depends On Cooling Water Or Air-Cooled Condensing Temperature, Which Sets The Whole Refrigeration Balance.
4. Purity And Product Mix. More Liquid Output And Higher Purity Both Consume Additional Refrigeration And Column Stages For The Same Nominal Size.
This Is The Point At Which Liquid Oxygen Plant Capacity Specifications Usually Need a Revision After a Site Survey, Because The Rating Condition And The Site Condition Rarely Match. Require The Supplier To Publish Capacity Against Ambient Temperature, Not a Single Point. A Responsible Cryogenic Air Separation Unit Offer Shows a Performance Curve Or At Least Two Rating Points, And States Which One The Guarantee Applies To. Where The Offer Shows One Number Only, Ask Which Month And Which Site That Number Belongs To.
Specify The Range You Will Actually Run In, Not Only The Peak. A Plant Sized On Peak Demand And Then Operated At Half Load Wastes Power And Capital.
Three Range Figures Belong In Liquid Oxygen Plant Capacity Specifications:
· Guaranteed Turndown. The Lowest Load At Which The Unit Still Delivers On-Spec Product, Stated As a Percentage Of Rated Output. Ask For The Specific Energy At That Load, Because Efficiency Usually Falls As Output Falls.
· Overload Capability. The Short-Duration Output Above Rating That The Machine Can Hold, With The Allowed Duration.
· Product Swing. Whether The Plant Can Move Between More Liquid And More Gas, How Fast, And What That Costs In Power.
Then Add a Capacity Margin Statement. A Common Buyer Error Is To Buy For a Five-Year Forecast, Which Produces a Machine That Runs Below Its Rating In Years One To Three. The Better Position Is To Specify Today's Duty, Then Require Spare Plot Space, Spare Utility Capacity And Documented Uprating Headroom.
One Product Page Publishes a Full Parameter Table, Covering Six Large Models From 11,000 To 20,000 Nm³/h Of Oxygen At 99.6% Purity, With Liquid Outputs And Footprint Listed By Model.
The Table Below Reproduces The Published Figures From The Large Air Separation Equipment Model Page, Including The Occupied Area Row.
|
Parameter |
Kdon(Ar)-11000/20000-300 |
Kdon(Ar)-12000/24000-400 |
Kdon(Ar)-13000/22000-350 |
Kdon(Ar)-16000/20000-520 |
Kdon(Ar)-18000/36000-600 |
Kdon-20000/20000 |
|
Oxygen Output, Nm³/h |
11,000 |
12,000 |
13,000 |
16,000 |
18,000 |
20,000 |
|
Oxygen Purity, % O2 |
99.6 |
99.6 |
99.6 |
99.6 |
99.6 |
99.6 |
|
Nitrogen Output, Nm³/h |
20,000 |
24,000 |
22,000 |
20,000 |
36,000 |
20,000 |
|
Liquid Oxygen Output, Nm³/h |
Not Listed |
Not Listed |
Not Listed |
Not Listed |
Not Listed |
800 |
|
Liquid Nitrogen Output, Nm³/h |
300 |
400 |
350 |
520 |
600 |
Not Listed |
|
Liquid Argon Output, Nm³/h |
Not Listed |
Not Listed |
Not Listed |
Not Listed |
600 |
Not Listed |
|
Power Consumption, Kwh Per Nm³ O2 |
1.3 |
0.85 |
0.68 |
0.68 |
0.65 |
0.65 |
|
Occupied Area |
140 |
150 |
160 |
180 |
250 |
420 |
Read The Table With The Following Checks, Each Of Which Is An Open Item Rather Than a Criticism:
1. Only The Last Model Lists a Liquid Oxygen Output. Converting 800 Nm³/h At About 700 Nm³ Per Tonne Gives Roughly 1.14 t/h, Which Is About 27 Tonnes Of Liquid Oxygen Per Day At Continuous Operation. That Is a Derived Figure, Not a Published Guarantee, So Request The Rated Tonnage For The Model You Are Quoting.
2. The Power And Nitrogen Purity Rows Carry a Comparison Operator That Is Mis-Encoded In The Page Source. Read Those Values As "No More Than" Figures And Confirm Before Republishing Them In Your Own Document.
3. The Occupied Area Row Is Published With a Cubic Metre Label. A Footprint Is An Area, So Confirm Whether The Intended Unit Is Square Metres And Whether The Figure Covers The Cold Box Only Or The Whole Plot Including Storage.
4. Liquid Argon Appears On One Model Only. Liquid Argon Co-Production Is a Column Decision, Not An Optional Accessory, So It Changes The Specification And The Power Figure.
5. Small And Medium Models Are Published By Kdon Model Designation Without a Parameter Table. Codes Such As Kdon-50/50, Kdon-100Y/20Y, Kdon-200Y/40Y, Kdon-120Y/120Y And Kdon(Ar)-1200Y/20Y Encode Products And Approximate Scale, But The Capacity Behind Each Digit Must Be Confirmed On The Datasheet. [Internal Link Suggestion: Small And Medium-Sized Air Separation Equipment -> Confirm Target Url Before Publishing]
Put Every Capacity Claim From Every Document Into One Table With Its Unit And Its Source, Then Reconcile. Conflicts Are Normal In This Equipment Class, And They Are Almost Always Unit Or Scope Conflicts Rather Than Dishonesty.
Four Conflict Types Recur, And Each Has a Standard Resolution:
|
Conflict Type |
Typical Appearance |
Resolution |
|
Unit Conflict |
The Same Plant Quoted In Nm³/h, t/d And Liquid Litres |
Convert Everything To One Basis With The Reference Temperature Shown |
|
Reference Condition Conflict |
Two Identical Output Figures, One At 0 °C And One At 15 °C |
Require The Basis Next To Every Number In The Offer |
|
Model Code Conflict |
A Title Capacity Claim That Does Not Reconcile With The Model Code Digits |
Ask Which Stream The Title Figure Describes And Request The Datasheet |
|
Scope Conflict |
Capacity Stated Without Pressure Or Purity At a Defined Point |
Fix The Battery Limit And Restate Output There |
Work Through One Example From The Manufacturer's Own Pages. A Product Page Carries The Title Claim 10 t/d Against The Model Code Kdon-200Y/40Y. If The Leading Digits Describe 200 Nm³/h Of Oxygen, The Arithmetic Gives About 6.9 t/d Of Liquid At a 700 Nm³ Per Tonne Conversion, So a 10 t/d Claim Cannot Be Reproduced From That Reading Alone And Must Describe Another Stream, Another Unit Basis Or a Differently Configured Machine. That Is a Question For The Supplier, Not a Defect To Argue About, And The Same Reconciliation Applies To Every Capacity Headline You Receive.
Conflicts Inside Liquid Oxygen Plant Capacity Specifications Are Usually Unit Or Scope Problems Rather Than Dishonesty. Three Verification Steps Close The Gap:
1. Request The Rated Data Sheet For The Specific Model, With The Reference Conditions Printed On It.
2. Request The Mass Balance For Oxygen, Nitrogen And Argon At The Guarantee Point.
3. Request The Acceptance Test Procedure That Proves Output, Purity And Specific Power At Your Site Conditions.
Nanjing Bangwin Gas Equipment Co., Ltd. Manufactures Cryogenic Air Separation Units, Psa And Vpsa Oxygen Plants, Nitrogen Generators, Booster Compressors And Industrial Gas Storage Tanks In China, Selling Under The Bangwin Brand. For Anyone Reviewing Liquid Oxygen Plant Capacity Specifications From This Supplier, The Practical Position Is That The Range Is Published By Model Family, And Only The Large-Series Page Carries a Complete Parameter Table.
Model Designations Follow The Kdon And Kdon(Ar) Convention, Where The Digits Describe Product Outputs, And The Smaller Units Are Published Without Full Data Sheets. Request The Rated Figures For The Specific Model Rather Than Reading Capacity From The Designation.
Company Performance Claims On The Site, Including a Stated Energy Saving Of 10% To 20% And a Long Design Service Life, Are Manufacturer Statements And Are Reported Here As Such. Ask For The Guarantee Basis And The Reference List Before Those Figures Enter An Investment Case. Send Your Specification, With Units And Reference Conditions Stated, And Ask For a Completed Parameter Table For Your Model.
One Tonne Of Liquid Oxygen Equals About 700 Nm³ Of Gas At 0 °C, So a Continuous Duty Of 100 Nm³/h Is About 3.4 Tonnes Of Liquid Oxygen Per Day. Divide The Hourly Gas Figure By 700 And Multiply By 24.
Both Are Gas Volumes At One Atmosphere, But Nm³ Uses 0 °C And Sm³ Uses 15 °C. The Same Physical Quantity Reads About 5.5% Higher On The 15 °C Basis, So The Basis Must Be Printed Beside The Figure.
Yes, In Practice. Higher Purity And Higher Liquid Output Both Consume Additional Refrigeration Duty And Column Stages, So a Plant Rated At One Purity Will Deliver Less Volume At a Higher Purity Unless It Was Sized For It.
Within Limits. Column, Compressor And Cold Box Sizing Set The Ceiling, While Plot Space, Electrical Supply And Cooling Capacity Set The Practical Ceiling. Ask The Supplier To State Uprating Headroom At The Design Stage Rather Than After Commissioning.
Size It From Cylinder Fill Volume Or Tank Evaporation Rate, Expressed In Nm³ Per Day, Then Add Autonomy For The Worst Realistic Supply Interruption. Medical Supply Also Has To Satisfy The Applicable Pharmacopoeia And Registration Route, Which Shapes The Specification As Much As The Number Does.
Some Suppliers Express Liquid Output As The Gas Volume It Would Produce, In Nm³/h, Rather Than As Tonnes Per Day. Ask Which Basis Is Used Before You Compare Two Quotations, Because The Two Figures Differ By a Factor Of Roughly 700.
Ask For The Mass Balance, The Rating Basis And The Site Performance Curve. Then Compare The Guaranteed Specific Energy With The Claimed Output, Because a Credible Offer Shows Both Moving Consistently With Plant Size.
State Every Capacity Figure With Its Unit, Its Reference Condition And Its Measurement Point, And Require The Same From Every Bidder.
Three Habits Prevent Most Disputes. Quote Liquid Product In Tonnes Per Day And Gas Product In Nm³/h, With The Basis Printed Alongside. Specify All Four Outputs, Oxygen, Liquid Oxygen, Nitrogen And Argon, Rather Than a Single Headline Figure. Ask For Performance Against Ambient Temperature Rather Than One Number At Reference Conditions, And Put The Acceptance Test And The Shortfall Remedy Into The Contract.
A Good Set Of Liquid Oxygen Plant Capacity Specifications Lets a Supplier Size The Machine Correctly And Lets You Compare Two Offers Honestly. Build The Specification From Your Own Measured Demand, Complete The Sixteen Fields, And Use The Conversion Factors In This Article To Check Every Figure You Receive Before It Reaches a Spreadsheet. When a Supplier Answer Arrives, Read It Against The Field List First And The Headline Number Second, Because a Specification That Is Complete On Paper Is Usually Priced Accurately Too.