WhatsApp / Mob : +86 156 5177 2521
e-mail : mrwin@cnbangwin.com
catégories
dernier blog
Mots clés
Industrial liquid oxygen plant for sale: Configurations, scope and delivery
Nov 12 , 2026An industrial liquid oxygen plant for sale is a complete cryogenic air separation package. It compresses and purifies air, distils it at cryogenic temperature, and delivers liquid oxygen at 99.5–99.8% purity. Packages are built to order rather than shipped from stock. Capacity, product slate and battery limit are fixed with the supplier first. A typical supply covers the compressor, purifier, cold box, expander, controls and liquid storage. Delivery then runs through factory testing, shipment, installation supervision and commissioning.
You can buy a cryogenic plant across a wide capacity range, with optional liquid nitrogen and argon. Bangwin's published range runs from about 50 nm³/h to 50,000+ nm³/h of oxygen.
Every industrial liquid oxygen plant for sale is configured around three product decisions. The first is capacity: How much oxygen you need per hour, at base load and at peak. The second is product state: Gaseous oxygen for a pipeline, liquid oxygen for storage and cylinder filling, or both. The third is the co-product slate: Liquid nitrogen, and argon where the market pays for it.
The catalogue follows a kdon naming pattern. Units in the current range include kdon(ar)-40y/40y, kdon-100/100, kdon(ar)-650/10y, kdon(ar)-1200y-20y and kdon(ar)-1500y/30y. Each designation is confirmed against your design basis, because the code alone does not define purity, pressure or battery limit.
That confirmation step is what separates a quotation from a catalogue page. Two buyers can request the same nominal capacity and receive different plants. One needs 99.6% liquid for medical cylinders, the other 99.5% gas for steel cutting. State your end use at inquiry stage, and the configuration follows. Units in this range are catalogued under small and medium-sized air separation equipment and large air separation equipment.
Every industrial liquid oxygen plant for sale should come with a written scope. The core package covers air compression through to the cold box and controls. Storage, civils, power distribution and freight usually sit outside it.
|
Scope item |
Standard package |
Typical add-on |
|
Air compressor and aftercooler |
Included |
— |
|
Molecular sieve purifier |
Included |
— |
|
Cold box, columns, heat exchanger |
Included |
— |
|
Turboexpander |
Included |
— |
|
Plc or dcs control system |
Included |
Remote monitoring |
|
Liquid oxygen storage tank |
Optional |
Vacuum-insulated tank, foundations |
|
Vaporizer and pressure control |
Optional |
Ambient or steam type |
|
Filling pump and manifold |
Optional |
Cylinder filling or tanker loading |
|
Electrical distribution |
Excluded |
Transformer, switchgear, cabling |
|
Civil works and bunding |
Excluded |
Foundations, control room, access |
|
Freight and insurance |
Excluded |
Ocean freight, heavy lift, inland |
|
Installation and commissioning |
Optional |
Supervision days, erection labour |
Mark every line as included, excluded or by others before you compare suppliers. A price without a battery limit drawing is not a price. It is a starting position for a later negotiation, and the later negotiation rarely favours the buyer.
Small demand suits a skid-mounted unit; larger demand needs a site-erected plant. For an industrial liquid oxygen plant for sale, the split follows logistics and civil works more than technology.
|
Configuration |
Typical buyer |
Product focus |
Catalogue examples |
|
Skid-mounted, small |
Cylinder fillers, fabricators, hospital backup |
Lox and lin |
Kdon(ar)-40y/40y, kdon-100/100 |
|
Site-erected, mid-size |
Regional gas distributors, glass, food freezing |
Lox, lin, optional lar |
Kdon(ar)-650/10y |
|
Site-erected, large |
Steel, mining, tonnage pipeline supply |
Gox and lox, lar |
Kdon(ar)-1200y-20y, kdon(ar)-1500y/30y |
Skid-mounted units arrive largely assembled and tested. That reduces site work and shortens the path to first production, which matters on islands and in congested plants. The trade-off is a ceiling on capacity and a tighter layout inside the frame.
Site-erected plants need foundations, structural steel and more crane time, but they scale and they run at lower specific power. A liquid business selling into cylinders and tankers usually fits the mid-size band. That band balances capital against unit cost.
Cylinder filling changes the design more than buyers expect. It adds a liquid pump, a vaporizer, a manifold and a filling scale system, and it changes the storage size. Say so at inquiry stage, or budget for a retrofit later.
Delivery of an industrial liquid oxygen plant for sale runs in five stages. Each stage ends in a document you can check, and the sequence is deliberately unremarkable.
1. Design basis and offer. You supply flow, purity, pressure, site conditions and product mix. The supplier returns a battery limit drawing and a priced scope.
2. Engineering and approval. P&ids, general arrangement, utility list and load list are issued for your review before fabrication starts.
3. Fabrication and factory acceptance test. Equipment is assembled, pressure tested and run at the works. You or your inspector witness the test against an agreed plan.
4. Shipment and site works. Skid units travel in containers; large cold boxes need heavy-lift planning. Foundations and power connection usually run in parallel.
5. Installation, commissioning and handover. Engineers supervise erection, leak test, cooldown, purity stabilization and the performance test.
For southeast asian projects, three logistics items deserve early attention. Port access and crane capacity decide the shipping split. Inland road limits decide whether the cold box travels in one piece. Humidity and ambient temperature decide the cooling design, which affects both price and output.
A factory acceptance test, a performance test, and a document package that should be listed in the contract.
The factory acceptance test proves the equipment was built correctly. The performance test proves it produces the contracted flow, purity and specific power. Those are different tests, and both belong in the contract with agreed measurement methods.
The document package for an industrial liquid oxygen plant for sale typically covers material certificates and welder qualification records. It also includes pressure test reports, as-built p&ids, the operations manual and the spare parts list. Medical oxygen projects add pharmacopoeia compliance and analytical documentation.
Third-party inspection is worth the cost on a first import. An independent inspector at the works catches fabrication defects while they are still cheap to fix. Confirm who pays for the inspector, and how many hold points the plan covers.
Ask for the inspection and test plan before fabrication. It tells you which hold points your inspector can attend, and which tests the supplier runs alone. A supplier who cannot produce an itp at quotation stage usually cannot produce one later either.
Seven items, all checkable before the first payment. They separate a plant purchase from a parts purchase.
The first is the battery limit drawing. Without it, scope is undefined and variations are inevitable. The second is a guaranteed specific power figure, in kwh per nm³ or per kg of liquid. It should carry a penalty clause. The third is a reference list with contactable sites in your region, not just photographs.
The fourth is inspection access, including hold points and third-party inspection rights. The fifth is the spare parts list with prices for the first two years, because imported spares dominate downtime cost. The sixth is the warranty terms in writing, covering both defects and performance shortfall. The seventh is the payment structure. Link each milestone to a verifiable event, such as design approval, fat or performance test.
An industrial liquid oxygen plant for sale is a long-life asset. Ten days spent on these seven checks saves months later. If a supplier resists any of them, treat that as information about how the project will run after signature.
Send a design basis, compare two or three scoped offers, then contract against milestones.
1. Send the design basis. Flow in nm³/h, purity, delivery pressure, liquid share, ambient conditions, site utilities.
2. Request scoped offers. Ask every supplier for the same document set: Battery limit drawing, specific power, schedule, spare parts list.
3. Compare like with like. Normalize scope before comparing totals, and convert to us$ per daily tonne.
4. Agree the contract. Fix the performance test method, inspection rights, delivery milestones and payment links.
5. Run the project. Attend fat, plan the site in parallel, and hold commissioning to the agreed test.
A turnkey enquiry and a split-package enquiry cover the same plant. Both describe an industrial liquid oxygen plant for sale, yet they produce different numbers. If you want a turnkey arrangement, say so at the first contact. Turnkey shifts coordination risk to the supplier, and it changes the price structure. Mixing turnkey and split-package quotes in one comparison produces a number that means nothing.
Send your design basis through the contact page. A written scope in return is more useful than a brochure.
Nanjing bangwin gas equipment co., ltd. Manufactures cryogenic air separation and liquefaction packages, and quotes against a defined battery limit rather than a headline capacity.
The company designs, manufactures and supplies industrial gas separation, liquefaction and waste-gas recovery equipment. Its public range covers small and medium-sized air separation equipment, large air separation equipment and psa oxygen generators. For liquid output, the cryogenic lines apply, because adsorption units deliver gas only.
The company states that its equipment runs in the philippines, malaysia, indonesia and other markets. Its units also operate across more than 30 chinese provinces. Those references matter for service response and spare parts logistics, which decide uptime more than the purchase price does.
The company also states that its large units are designed for a service life above 25 years. It claims 10%–20% energy savings against conventional designs. Treat both as company claims, and tie them to guaranteed performance data in the contract.
For a liquid oxygen plant, ask for four things before price. They are the battery limit drawing, the guaranteed specific power, a regional reference list and the inspection and test plan. Any serious industrial liquid oxygen plant for sale should come with all four.
For any industrial liquid oxygen plant for sale, start from base load rather than peak. Size the plant for steady demand and cover peaks with storage or delivered liquid. A plant running far below its design point wastes power and controls poorly.
It depends on capacity, cold box fabrication slots and shipping route. Ask for a milestone schedule instead of one total figure, and tie payment to milestones the supplier controls.
Yes, with a filling package added. That means a cryogenic pump, a vaporizer, a manifold and a filling scale system. It also changes storage sizing, so specify it at inquiry stage.
Standard cryogenic plants deliver 99.5–99.8% oxygen. Higher grades need additional purification. Medical supply adds pharmacopoeia compliance and analytical documentation on top of the purity figure.
It depends on the contract. Most packages include supervision, not erection labour. Confirm supervision days, travel and accommodation terms, and who supplies cranes and consumables.
The main air compressor dominates the load, usually on medium-voltage motors. Ask for a single-line diagram and a load list with the offer, then confirm transformer capacity with your utility.
Compressor overhaul kits, expander bearings, analyser cells, valve actuators and control spares. Ask for two years of critical spares priced with the plant, and confirm lead times in writing.
Yes, with the appropriate configuration. Liquid nitrogen comes at low incremental cost. Argon needs an extra column and adds capital, so justify it with a real offtake.
The plant is engineered, not stocked. Fix the design basis, define the battery limit, and contract against tests.
An industrial liquid oxygen plant for sale is a project with a machine inside it. Capacity, purity and product slate set the design. Battery limits, freight and installation set the budget. Performance guarantees and spare parts set the operating outcome.
Three documents decide whether the purchase goes well. They are the battery limit drawing, the performance test method and the spare parts list. Ask for all three before you discuss price. If they arrive late or incomplete, the project will run late too.
Send three inputs first: Base and peak oxygen demand, the purity you must meet, and storage autonomy in days. Those three decide most of the plant. Suppliers answer a defined scope faster and more accurately than an open question. Then compare suppliers on the same documents, not on the same headline number, and the choice becomes straightforward.